This is an old revision of the document!


500LCD - Colour LCD Screen

support.e-plex.co_product_photos_500ccm.jpg
E-Plex economy slim LCD display and integrated electroluminescent backlight.

Links

Frequently Asked Questions

How do I re-calibrate the touch screen?

The following instructions describe the touch screen calibration procedure for the 500CCM. Note that there are separate instructions for recalibrating the 500CCM.

  1. Connect the clock module to a PC via the USB connection, and open E-Logic.
  2. Open the E-Logic design file for your system.
  3. From the compile menu, select Open E-Plex interface.
  4. Click on the Stop Streaming button.
  5. If you have not already done so, program the clock and the LCD.
  6. In the module selector area, choose (500LCD) from the drop-down list.
  7. Click on the Open Module Test Program button.
  8. Click on the Re-calibrate touch button.
  9. Close the module test program.
  10. Start streaming
  11. The 500LCD display will now ask to you press on the highlighted regions. For best results you should use something hard and pointy (but not sharp).

Why is the touchscreen larger than the LCD?

A space is provided at the edge of the LCD to insert a printed graphic. Typically, this would include controls to switch the LCD display on and off. The 500CCM can be programmed to switch off the LCD after an amount of inactivity, but the power buttons will still be visible. This can also be used for commonly used menu functions, such as a link to the home page.

Programming the graphics on a 500LCD takes a long time. Is there a faster way?

Yes, it is much faster to program the module as a 500CCM than as a 500LCD. The procedure is as follows:

  1. Create a copy of your design.
  2. If you have not yet converted the 500CCM to clock mode, skip to step 11.
  3. Connect the USB or serial cable to the actual clock used in the system.
  4. Connect the 500LCD to the clock with an E-Plex bus cable.
  5. Open the E-Plex interface.
  6. Select the 500LCD in the module selector.
  7. Clock on Open Module Test Program.
  8. Untick the box labelled Disable Clock Mode.
  9. Close the E-Plex interface.
  10. Completely disconnect the original clock.
     
  11. Connect the USB on the 500LCD (currently a 500CCM) to the PC.
  12. Delete the clock from your design.
  13. Open the object selector.
  14. Select the EPLEX - CLOCKS object group.
  15. Select 500CCM.
  16. Click once in the design to add a 500CCM.
  17. Click Close.
  18. From the Compile menu, select Update Part Addresses.
  19. Re-connect the wires that were connected to 450 clock to 500 clock.
  20. Make a note of the address assigned to the 500CCM object.
  21. From the View menu, select Layout Manager…
  22. Select the 500LCD in the module list.
  23. Click on the Reassign… button.
  24. Enter the address of the 500CCM (from step 19).
  25. Click OK.
  26. Close the Layout Manager.
  27. Open the E-Plex interface.
  28. Select the clock from the module selector (last item in the list).
  29. Click on Open Module Test Program.
  30. Click on Write Design, and wait for the process to complete.
  31. Click on Write All Backgrnd, and wait for the process to complete.
  32. Tick the box labelled Disable Clock Mode.
  33. Close the module test program.
  34. Close the E-Plex interface.
  35. Close the modified design.
     
  36. Disconnect the 500LCD from the PC.
  37. Re-connect the original clock.
  38. Open the original design.
  39. Open the E-Plex interface.
  40. Press Program All.
hardwarepub/modules/500lcd.1456143028.txt.gz · Last modified: 2016/02/22 12:10 by Bob Lynas
 